12/24/40.5kV Conventus foriculae et interlocking
Lorem Conventus 5GP.320.010 Installation Diagram
(800mm width media posita switchgear)
Lorem Conventus 5GP.320.010 Dispositio List
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
1 | Jus supporting bracket | 8GP.123.011 | 1 |
2 | Ius nexum laminam | 5GP.235.011 | 1 |
3 | Indicating tag | 8GP.866.014 | 1 |
4 | Connexionem sinistram | 5GP.235.010 | 1 |
5 | bracket supporting sinistram | 8GP.123.010 | 1 |
6 | Connection welding | 5GP.174.016.1(Ad VD4) | 2 |
5GP.174.016.2(Pro GPVN) | |||
5GP.174.016.3(Pro VB2). | |||
7 | Lorem porta | 8GP.320.010 | 1 |
8 | Stipes Metronactis 8 | DK-8 | 8 |
9 | Bracket plate | 8GP.123.013 | 3 |
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
10 | Connection welding | 5GP.174.017.1(Pro VD4, 40kA) | 2 |
5GP.174.017.2(Ad VD4, 31.5kA) | |||
5GP.174.017.3(Pro GPVN) | |||
5GP.174.017.4(Pro VB2) | |||
11 | Indicating tag | 8GP.866.012 | 1 |
12 | Indicating tag | 8GP.866.013 | 2 |
13 | Bracket plate | 8GP.123.012 | 3 |
14 | Lorem superius | 8GP.320.011 | 1 |
15 | dux rod | 8GP.234.011(Ad VD4, GPVN) | 2 |
8GP.234.011.1(Pro VB2) | |||
16 | Stopper sleeve | 8GP.210.011 | 2 |
Alia species Lorem ordinatio list
Code | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
scrinium latitudo | 650mm | 700mm | 840mm | 900mm | 1000mm |
Porta superior | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Porta descendit | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Lorem Conventus 5GP.320.011
(1000mm latitudine mediae positae switchgear)
Lorem Mechanismum Fabrica 5GP.320.011 Dispositio List
(1000mm latitudine mediae positae switchgear)
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
1 | Jus supporting bracket | 8GP.123.276 | 1 |
2 | Ius nexum laminam | 5GP.235.012 | 1 |
3 | Indicating tag | 8GP.866.014 | 1 |
4 | Connexionem laminam sinistram | 5GP.235.013 | 1 |
5 | bracket supporting sinistram | 8GP.123.275 | 1 |
6 | Nexum conventum | 5GP.174.281 | 2 |
7 | Lorem descendit | 8GP.320.273 | 1 |
8 | Stipes Metronactis 10 | DK-10 | 8 |
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
9 | Bracket plate | 8GP.123.278 | 3 |
10 | Connection iuncturam glutino | 5GP.174.282 | 2 |
11 | Indicating tag | 8GP.866.012 | 1 |
12 | Indicating tag | 8GP.866.013 | 2 |
13 | Bracket plate | 8GP.123.277 | 3 |
14 | Lorem superius | 8GP.320.274 | 1 |
15 | dux rod | 8GP.234.272 | 2 |
16 | Stopper sleeve | 8GP.210.011 | 2 |
Alia species Lorem ordinatio list
Code | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
scrinium latitudo | 800mm | 1000mm (Insulating) | 1100mm | 1200mm |
Porta superior | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Porta descendit | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Nota: 5GP.320.275 est ad claustrum insulare per SMC laminam in medio et utrumque finem per laminam ferream, alia Lorem conventus, si opus est, porta insulating Quaeso.
Earthing switch operation mechanism interlock device (Ad nexum brachium coegi operatio) 5GP.363.010.1 conventus diagram
Instructio Interlock Fabrica
Instrumentum interlock additur e converso interlock cum ostio postico quae ex originali 5GP.363.010 fabricandi machinam machinam interlockam machinam transibit.Hoc est, post transitum terreum clausum et ostium posticum (laminam obsignare), interlock originale adhuc potuit transitum terrestrem operantem, sed hoc interlock non potuit.Primum ostium posticum (laminam obsignandi) claudere debes ut transitum terrestrium operetur.
Principia operativa artificii interlock mutatur in No. 24 manica obfirmatis ad id quod ostendit dextrorsum et ver additum in fundamento originalis 5GP .363.010.Cum ostium posticum (laminam obsignandi) apertam, manica manica in quadratum foraminis arcae (commendatae magnitudinis 35X35), commutatio terrestris operari non potest.
Earthing switch operatio mechanism interlock fabrica (nam nexum brachium coegi operatio)
5GP.363.010.1 album collocatio.
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
1 | Ferens | 8GP.263.011 | 1 |
2 | Pars | 8GP.192.010 | 1 |
3 | Pars | 8GP.192.011 | 1 |
4 | Axis sleeve | 8GP.210.014.1 | 2 |
5 | Pars | 8GP.151.041 | 1 |
6 | Axis sleeve | 8GP.211.061 | 1 |
7 | Pars | 8GP.151.039 | 1 |
8 | Axis sleeve | 8GP.211.062 | 1 |
9 | fulmen M5×12 | GB70-85 | 1 |
10 | Pars | 8GP.151.042 | 1 |
11 | Pars | 8GP.151.043 | 1 |
12 | Operatio virga | 8GP.200.013.1 (Longum 1432 pro arcae profunditatis 1500 profunde); | 1 |
8GP.200.013.2 (Longum 1590 pro arcae profunditate 1660) | 1 | ||
13 | Supportantes laminam | 8GP.161.058 | 1 |
8GP.161.058.1(Pro optione) | 1 |
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
14 | Cover | 8GP.017.011.1 | 1 |
15 | Bracket | 5GP.043.022 | 1 |
16 | Supportantes laminam | 8GP.161.059 | 1 |
17 | Slider | 8GP.143.010 | 2 |
18 | Axis sleeve | 8GP.211.058 | 1 |
19 | Stopper sleeve | 8GP.211.057 | 3 |
20 | Basi Support | 8GP.043.019 | 1 |
21 | Prope significat | 8GP.866.010 | 1 |
22 | Connection virga ecclesiam | 5GP.233.030.1 | 1 |
5GP.233.030.3 (Pro optione | 1 | ||
23 | Apertum significat | 8GP.866.011 | 1 |
24 | Obstructio sleeve | 8GP.211.201 | 1 |
25 | Dens obturaculum laminam | 8GP.151.044 | 1 |
26 | Axis sleeve | 8GP.211.060 | 2 |
27 | Tag | 8GP.860.010 | 1 |
28 | Pressura vere | 8GP.282.201 | 1 |
29 | Obstructio sleeve figens fulmen | 8GP.920.002 | 1 |
Nota:
1. N. 1~12 vide paginam priorem.
2. N. 22 Connexio virgae congregationis, connexio brachii duo habet magnitudinem: scrinium centrum distantiae 60mm in communi.Si opus est 80mm centri intervallum, sis pagina 17 nexum bracchium coetuum inspiciendum, ac ordinandum denota.
Earthing switch operatio mechanism interlock fabrica (nam revellere calces coegi operatio) 5GP.577.1001
Earthing switch operatio mechanism interlock fabrica (nam revellere calces coegi operatio) 5GP.577.1001 Ordinatio list
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
1 | Ferens | 8GP.263.011 | 1 |
2 | Stopper laminam | 8GP.151.084 | 2 |
3 | Axis sleeve | 8GP.210.014.1 | 2 |
4 | Pars | 8GP.151.041 | 1 |
5 | Axis sleeve | 8GP.210.014.2 | 1 |
6 | fulmen M 5X12 | GB70-85 | 1 |
7 | Pars | 8GP.151.042 | 1 |
8 | Pars | 8GP.151.043 | 1 |
9 | Axis sleeve | 8GP.210.014.3 | 1 |
Nec. | Nomen | Ducto no. | Qty.(pc/set) |
10 | Stopper sleeve | 8GP.210.322 | 1 |
11 | Operatio virga | 8GP.174.214 | 1 |
12 | Cover | 8GP.017.011.2 | 1 |
13 | Basi Support | 5GP.043.022 | 1 |
14 | Slider | 8GP.143.010 | 2 |
15 | Supportantes laminam | 8GP.161.059 | 1 |
16 | Supportantes laminam | 8GP.161.058 | 1 |
17 | Dens obturaculum laminam | 8GP.151.044 | 1 |
18 | Tag | 8GP.860.010 | 1 |
Nota: 1. Haec mechanismus e ostio implicatur, Quaeso cum ordinatio.