GPN2S/GPN2E-40.5kV Cubiculi genus Gas Insulated Switchgear
Summarium
Genus cubiculum Gas Insulatum Switchgear (CGIS) est umbracula, officina congregata, metallo inclusa, genus cubiculi switchgear gas- insulatum pro singulis applicationibus busbaricis, in quibus "Type viridis" GPN2E-40.5, GPN2N-40.5 et "Latin Type" GPN2S- 40.5.
"Type viridis" GPN2N-40.5 innovatum est uti nitrogenium purum sicut gas insulationis pro serie producti cum technologia gasi Non-SF6, quae genuinum praesidium environmentale gasi switchgearis insulatae intulit.
"Type viridis" GPN2E-40.5 technologiae progressae gas- insulatae mixtae (SF6+N2) incorporat et vacuum praevaricatoribus praebens apparatum ad operandum certius et environmentally- amicissime.
The "vexillum genus" GPN2S-40.5 est ex C% SF6 insulatas, altae operationis et facilis usus.
Cum modernis fabricandis digitalis et automaticis probatione coniuncta cum sensori, monitori et technologiae tutelae, CGIS apta est apta distributioni potentiae.CGIS maxime convenit industriis cum firmitate requisita ut Potentia Networks, Mining, Rail Transportatio, Plantarum Petrochemicarum, Ventorum Fundorum et Metropolitanae Rail Systems.
Normalis operating conditionibus
Switchgear fundamentaliter destinatur ad condiciones servitii normales pro switchgear ad GB 3906, DL/T404 et IEC 62271-200.Sequens limites valores, inter alios, applicant;
Ambiens aer temperatus
Maximum aeris temperies: +45℃
Temperatura aeris minima: -25℃
Cotidiana mediocris maximus temperatus: +35℃
Uvor;
Cotidiana mediocris valor relativae humiditatis: ≤ XCV%
Menstrua mediocris valor humiditatis relativae: ≤ XC%
Cotidiana mediocris valor aquae vaporum pressura: ≤ 2.2×10-3MPa
Menstrua mediocris valor aquae vaporum pressura: ≤ 1.8×10-3MPa
Altitude: ≤ 1000m
Aer ambiens non signanter inquinatur pulvere, fumo;
mordax et/vel vapores flammabiles, vapores vel sal.
Specialis muneris condiciones
Productum etiam applicari potest ad multas condiciones speciales muneris.
In casu servitii condiciones normales condiciones muneris excedunt, quae extra mensuram GB 11022 et IEC 62271-1 sunt, consule cum GP in antecessum ad confirmationem:
Altitudo altior quam 1000m.
Aliquam ut dictum tortor.
Aliquam tortor inferior.
Aliae conditiones speciales environmental.
Redigendum CONSERVATORIUM gas emissiones
CGIS technologias progressas puri Nitrogenis vel mixti gasi insulatae (SF6 + N2) incorporat et ruptores vacuos, electionem fundamentalem GP factam, adiuvandi ad effectum deducendi CONSERVATORIUM.SF6 (sulphur-hexafluoride ) est in catalogo gasarum conservatoriarum in Protocollo Kyoto, cum Potentiale Global Warming (GWP) 23,000.Multae aliae mediae intentionis systemata switchgear SF6 gas ut solum media insulating utuntur.Lacus SF6 gasi ex switchgear confert comminationem conservatoris effectus et adiuncti mutationis climatis.
Cum nostro studio ad tutelam ambitus, CGIS adiuvat emissiones gasi conservativas reducere utendo technologiae gas- insulatae mixtae simul cum technologia vacuo commutandi.
A 100% vel 50% reductionem in SF6 obtinet utendo Nitrogenio (N2) contritiones gas- insulatas mixtae.NITROGENIUM maximum elementum aeris eiusque arcus compositione producti non-toxicus est.Coniunctis per obturaculum in connexionibus et natura modularis tabularum facilitatem institutionis et extensionis efficit sine necessitate actionis extra gas tractandi in-situm.
Commodum
●LXX% reductionem in Switchroom Location
Consilium campi electrici optimized cum praestantia operatione insulating coniuncta, consequitur in pactione productum switchgear quod tuto et fideliter operatur.
Salvum 70% spatium cum switchgear aere insulato comparatum.
Retrofittatio existendi switchroom facilis est.
Redigendum sumptus de terra substation.
Maximum Salutis pro operante et Equipment
Pressura functionis minima cubiculi est 0.00MPa(20℃).Quod significat, etiam sub tantis condicionibus, etiamnum gradum insulationis aestimatae conservat et omnem suam functionem aestimatam servat.Propter gravem pressionem gasi, etsi gas e switchgear fugit, cubiculum adhuc agere potest.Certae electricae et mechanicae interlocks ordinantur inter praevaricatorem ambitum et tres positiones switch ad praecavendam misoperationem.
Securus instruitur / Operatio et Sustentacionem Sumptus Low
Tabulae in medio tolli facile possunt ad victum, sine tabulis vicinis movendis, magisque disponibilitate.
Technical Parameters
Generalis | Unitas | Latin type GPN2S-40.5 | Green Type GPN2E-40.5 | Green Type GPN2N-40.5 | |
Rated voltage | kV | 36/38/40.5 | 36/38/40.5 | 36/38/40.5 | |
Rated potentia frequency voltage sustinere (1min) | Ad terram / tempus ad tempus | kV | 95 | 95 | 95 |
Per solitudinem spatium | kV | 118 | 118 | 118 | |
Ad terram / tempus ad tempus | kV | 185 | 185 | 185 | |
Per solitudinem spatium | kV | 215 | 215 | 215 | |
Rated frequency | Hz | 50/60 | 50/60 | 50/60 | |
Ratum current | A | 1250, 2500, 3150 . | 1250, 2500 | 1250, 2500 | |
Una capacitor ripae fractionis facultatem | A | 400/400 | 400/400 | 400/400 | |
Rated funem præcipiens fractionis current | A | 50 | 50 | 50 | |
Rated shortcircuit fractionis current | kA | 20/25/31.5 | 20/25/31.5 | 31.5 | |
Ratum ambitum brevem currentem faciens (cacumen) | kA | 50/63/80 | 50/63/80 | 80 | |
Ratum est breve tempus sustinere currenti et patientiae tempore | KA/s | 20/3, 25/3, 31.5/3s . | 20/3, 25/3, 31.5/3s . | 31.5/3s | |
Rated apicem sustinere current | kA | 50/63/ 80 | 50/63/ 80 | 80 | |
Sequentia operating | O-0.3s-CO-180s-CO | O-0.3s-CO-180s-CO | O-0.3s-CO-180s-CO | ||
Gas systema insulatas aliasque gas | 100% SF6 | L% SF6+50%N2 | 100% N2 | ||
Annua rate lacus | %/Y | ≤ 0.1 | ≤ 0.1 | ≤ 0.1 | |
Gas pressura aestimavit (abs, 20˚C) | MPa | 0.12 | 0.12 | 0.12 | |
Terror pressus (abs, 20˚C) | MPa | 0.11 | 0.11 | 0.11 | |
Minimum operating pressionis (abs, 20˚C) | MPa | 0.10 | 0.10 | 0.10 | |
Gradus Praesidium Gas tank | IP65 | IP65 | IP65 | ||
Clausura | IP4X | IP4X | IP4X | ||
Motricium et iter coil Circuit ruptor stultum quid motricium | W | 90 | 90 | 90 | |
Rated potentia claudendi coil | W | 220 | 220 | 220 | |
Rated potentia aperiendi coil | W | 220 | 220 | 220 | |
Aestimavit intentionem circuli auxiliaris | V | DC 24, 48, 110, 220;AC220 | DC 24, 48, 110, 220;AC220 | DC 24, 48, 110, 220;AC220 | |
1 min potentia frequentiae intentionem circuli auxiliorum sustinendi | kV | 2 | 2 | 2 | |
Dimensiones et pondus Dimensio (W×D×H) 1250A | mm | 600×1600×2400 | 600×1500×2400 | 800×1700×2300 | |
Dimensio (W×D×H) 2500A | mm | 800×1600×2400 | 800×1500×2400 | 900×1700×2300 | |
pondus 1250A | kg | 800 ~ 1000 | 800 ~ 1000 | 800 ~ 1000 | |
pondus 2500A | kg | 1100 ~ 1400 | 1100 ~ 1400 | 1100 ~ 1400 |
Structura speciei vexillum GPN2S-40.5 et generis viridis GPN2E-40.5
Standard type GPN2S-40.5kV
Viridis genus GPN2E-40.5kV
1. Praesidium et imperium Unit
2. Minimum voltage cellula
3. VCB mechanism
4. Polus vacuus embedded ambitum ruptor
5. Minimum voltage cellula ostium
6. Gas densitatis indicator
VCB Gas cisternina
8. III-situ switch mechanism
9. III-situ switch
Main 10. busbar
Main busbar Gas cisternina
12. Front cover
13. Surge arrester
14. Impetus subsidio fabrica principalis busbar Gas cisternina
15. funem interiorem conum bushing
16. Cable terminatio
17. cables
18. Audi operimentum
19 Impetus subsidio machinam VCB Gas cisternina
20. CT .
IST 3-situ mechanism
IST III-situ switch
GPN2S VCB gas tank
GPN2S-40.5 VCB
Structura speciei vexillum GPN2S-40.5 et generis viridis GPN2E-40.5 Structurae generis viridis GPN2N (No-SF6)
Genus viridis GPN2N-40.5kV
1. Praesidium et imperium unitas
2. Minimum voltage cellula
3. VCB mechanism
4. Polus vacuus embedded ambitum ruptor
5. Minimum voltage cellula ostium
6. Gas densitatis indicator
VCB Gas cisternina
8. III-situ switch mechanism
9. III-situ switch
Main 10. busbar
Main busbar Gas cisternina
12. Front cover
13. Surge arrester
14. Impetus subsidio fabrica principalis busbar Gas cisternina
15. funem interiorem conum bushing
16. Cable terminatio
17. cables
18. Audi operimentum
19 Impetus subsidio machinam VCB Gas cisternina
20. CT .
21. Earthing bar
22. TRANSFIGURATOR intentione (libitum)
Vacuum ambitus ruptor insidens fixus est, cum eius tres periodi infixae poli verticaliter in piscinam gasi rupti ambitum dispositae sunt.
Ob technologiam vacuum mutandi, arcus in vacuo interpellatore limitatur, reducendo volumen gasi insulationis exhaurit.Vacuum commutatio altae effectus est in frequenti brevi-circuitu ac numerosae applicationes in-onere mutandi.