Vacuum Load Switch Fuse Composita Apparatus
Exemplar et Sensus
Ambiens Condition
Mauris tempor: Max.temp.+40℃;Min.temp.-15℃
Humiditas environment: Relativa humiditas per diem ≤ 95%;Relativum humiditas per mensem ≤ 90
Altitude situs ubi SWITCH PB ministerium in potest pervenire 1000m
Ad specialem condicionem muneris, pete fabricatorem contactus
Reference Standard
GB3804-2004 Altus Voltage alternae venae permutationes pro aestimatae intentione supra 3.6kV et usque ad 40.5kV recensentur.
GB16926-2009 High-Voltage alterna-current switch-fuse combinations
GB/T11022-1999 Communia specifications pro summo voltage switchgear et controlgear signa
Pelagus Technical parametri switch
Nomen | Unitas | Switch GPL-24/T630-20 | Fuse deducto switch- GPLR-24/T125-40 | |
Rated voltage | kV | 24 | 24 | |
Rated frequency | Hz | 50 | 50 | |
Ratum current | A | 630 | 125 (sicut per fuse) | |
Ratum Insulation level | 1min potentia frequency voltage sustinere | kV | Terminalia contactus cum aper- tores 65; Phase ad Phase, Phase ad Terram 65" | |
Levamen impetum sustinere voltage | kV | Phase to phase, phase to earth 125; Terminatio contactus cum isolators aperta 125 | ||
Ratum brevis circuitio praevaricationis current | kA | . | 40 | |
Active onus fractionis current | A | 630 | . | |
Rated claudendo loop fractionis current | A | 630 | . | |
Active onus humilis current fractionis | A | 31.5 | . | |
Rated funem præcipiens fractionis current | A | 16 | 16 | |
Aestimavit ambitum brevem currentem faciens (apicem) | kA | 50 | 100 | |
Rated breve tempus sustinere current | kA | 20 | . | |
Rated breve tempus sustinere current durationem | S | 4 | . | |
Rated apicem sustinere current | kA | 50 | . | |
Rated ne-super current | A | . | 3150 | |
Ambitus resistentia | μΩ | ≤150 | ≤250+ Fuse | |
Motor potentia | W | 90 | ||
Movens et fixum contactum licitum abrasio accumulativa crassitudine | mm | 3 | ||
Alvi inter aperta contactus | mm | 12±1 | ||
Contact claudendo proiectione temporis | ms | ≤2 | ||
Asynchronous tempus III- | ms | ≤2 | ||
Mediocris claudendo velocitate | m/s* | 0.8±0.2 | ||
Mediocris ostium celeritas | m/s* | 1.3±0.2 | ||
Mechanica patientia | Tempora | 10000 |
Pelagus Technical parametri Motor
Nomen | Unitas | Morbi laoreet |
Rated operatio voltage | V | AC/DC 110/220 |
Potentia initus rated | W | 80 |
Normalis intentione range praecipientes motor |
| 85%~ 110% Rated operatio voltage |
dato tempore | s | ≤15 |
Pelagus Technical de Coil
Nomen | Unitas | Morbi laoreet | |
Rated operatio voltage | V | AC, DC110 | AC, DC220 |
Operatio current rated | A | ≤3 | ≤2 |
Normal intentione rhoncus prope orbem |
| 85%~ 110% Rated operatio voltage | |
Normalis intentione range iter coil |
| 65%~ 120% Rated operatio voltage |
Structura et Functio
GPL(R) genus switch consistit ex mechanismo et arcu-extinguentis cubiculis anterius dispositio, eius ambitus principalis conductivus fundi structurae exemplar est.Vacuum arcus exstinguentis cubiculum in directo insulationis columnae cannulares structurae epoxyi resinae ab technologia APG factae figitur, ergo cum optima anti-creepage Talis compages magna designatur quae coacervationem pulverum in superficie cubiculi vacui arcus exstinguentis reducit; quod non solum potest impedire cubiculum vacuum ab extra influentiam exstinguere, sed etiam efficere ut status contra effectum voltationis altae resistentiae exhibeat vel in calore aquoso vel in ambitu gravium pollutionis.
Veris mechanismus operans in dispositione plani disposita accusari potest a manuali vel motore, mechanismo operante in capsa ferrea ante cubiculi arcu-extinguentis fixa.Cista in quinque spatium conventuum a quattuor clangoribus dividitur, in hoc spatio sunt sectio, sectio tribuo, sectio solvens et quiddam mechanismi separatum.Fabricae GPL(R) structurae genus, quod machinatio mechanismi et cubiculi arc-exstinguis in extensionem integram ordinatae sunt, bene aequare potest operandi mechanismi operandi et perficiendi necessarii ad frangendum et fabricandum cubiculi arcus exstinguendi.Item, potest reducere terminos supervacuos medios et strepitum et industriam consumptam reducere ergo ad operationem operationis GPL(R) multae certae ducere.